Benefits:
- NBV No Bleed Valves minimize
atmospheric emissions by eliminating bleed gas when the control valve
is in a full open and/or full closed position.
- No adjustment
- Modular design minimizes
tubing and fittings
- Only one moving part
- Easy retrofit to all existing
Becker double acting instrumentation
Compatibility:
NBV No Bleed Valves are compatible
with ALL Becker double acting instrumentation:
- VRP Model Pilots
- VRP-B Model Pilots
- HPP-2 Model Positioners
- HPP-2E Model Positioners
- HPP-3 Model Positioners
- HPP-3E Model Positioners
Note that Becker
single-acting instrumentation do NOT utilize Non-Bleed Sensors.
|
Usage:
NBV No Bleed Valves are typically
used when double-acting control valves remain in a full open and/or full
closed position such as monitor or standby regulators.
NBV No Bleed Valves are utilized
when the following conditions exist:
- 75 psig > Psupply
< 150 psig
- Pdischarge <
60 psig
|